Lentille aspérique à infrarouge 3MP à diaphragme automatique DC varifocale
NONE
-
2.7-12mm
-
CS-Mount
-
1/3" : P :125,2°~30,3° H :97,2°~24,3° V :71,5°~18,2°<br>1/4" : P :91,2°~22,9° H :72,1°~18,4° V :53,6°~13,8°
© Hangzhou Hikvision Digital Technology Co., Ltd. All Rights Reserved.
Développement Web par 8P-Design
IMPORTANT! Ce modèle nécessite un logiciel non standard. N'installez pas de logiciel standard (par exemple, v.4.1.xx) sur ce modèle. Cela endommagerait définitivement votre système. Vous devez utiliser le logiciel personnalisé v.4.1.25 à partir de la page du produit iDS-9632NXI-I8/16S
View the most updated version of this document here:
The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.
As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.
Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.
Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.
View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience.
Database Optimization and Repair
As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
Preparing the Upgrade
Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.
Action after firmware upgraded
1. Upgrade the DVR according to the chart above.
2. Reconfirming Channel's Recording Schedule
- Confirm channel's recording schedule is enable.
- Check if the channel is on correct recording schedule.
3. Double Check Storage Setting
- Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode.
4. Perform Database Rebuild locally.
• Some version above support Database Rebuild via web access - K51 and K72
• Perform Database Rebuild regardless if system is having any database issue symptom.
• Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.
• After Database Rebuild - Check log to confirm Database Rebuild has went thru properly.
• If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.
• To check log > System > Log > Information > Database Rebuild Started and Stopped.
• If the log option is not available - access system via SSH can also obtain similar result.
5. Recording Data is still missing after database rebuild process.
If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.
In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”
These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.
The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:
Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.
In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs
These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.
The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:
Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.
En téléchargeant et en utilisant des logiciels et autres matériels disponibles sur ce site, vous acceptez d'être lié par les Conditions Générales d'Utilisation de HIKVISION. Si vous n'acceptez pas ces conditions, vous ne pouvez télécharger aucun de ces documents. Si vous êtes d'accord sur votre entreprise, vous déclarez et garantissez que vous avez le pouvoir de lier votre entreprise aux Conditions Générales d'Utilisation . Vous déclarez et garantissez également que vous avez l'âge légal de la majorité dans la juridiction dans laquelle vous résidez (au moins 18 ans dans de nombreux pays).