Company News

novembre 02, 2020
Organizations in all industries face new demands to ensure the safety of employees and visitors, while delivering a...
octobre 21, 2020
Sherwin Xing, directeur régional des ventes de Hikvision au New Jersey, aide à préparer des sacs à dos remplis de...
octobre 16, 2020
As businesses look toward the future, they need to find ways to adjust to the new normal. While the pandemic has made...
octobre 14, 2020
Our new online brochure, “Facility Self-Screening with Questionnaire,” details Hikvision’s all-in-one solution that...
octobre 08, 2020
Hikvision has added new product models online that feature interactive, virtual 3D product modeling to help...
septembre 11, 2020
Schools and educational campuses face a slew of challenges as students and staff return for the new school year....
septembre 11, 2020
Schools and educational campuses face a slew of challenges as students and staff return for the new school year....
septembre 01, 2020
Get instant, elevated skin-surface temperature screening at a safe distance using Hikvision’s Highly Accurate...
août 27, 2020
Hikvision has released a new flyer that details its solutions for a safe return to schools and campuses: “All-In-One...
août 24, 2020
Hikvision’s Highly Accurate Thermographic (HAT) Handheld Camera provides instant, accurate temperature screening. It’s...
août 20, 2020
Hikvision propose une gamme de solutions qui aident les entreprises à reprendre leurs activités en toute sécurité. Les...
août 19, 2020
Hikvision USA Inc. avait annoncé l'ouverture de son Centre de transparence du code source, le premier du genre dans le...
août 18, 2020
Our Temperature Screening Terminal integrates with access control to provide safe and accurate temperature screening...
août 17, 2020
Une nouvelle vidéo sur notre chaîne YouTube présente la certification FIPS 140-2 de Hikvision, qui a ajouté une autre...
août 14, 2020
Hikvision a été désignée par Mitre Corporation en tant qu'autorité de numérotation des vulnérabilités et expositions...
août 10, 2020
Hikvision’s DS-K1T671TM-3XF Temperature Screening Terminal is an access control device integrated with high accuracy...
août 07, 2020
Our Highly Accurate Thermographic (HAT) solutions offers a comprehensive line of products to pre-screen instantly for...
juillet 30, 2020
Soyez en sécurité avec un dépistage instantané et précis de la température grâce à la caméra à tourelle...
juillet 27, 2020
Hikvision has released a new brochure about our Walkthrough Metal Detector with Built-in Temperature Measurement that...
juillet 24, 2020
Hikvision a publié sa brochure sur les solutions de distanciation physique et de densité sociale, maintenant...
juillet 22, 2020
Nous sommes heureux d'annoncer le lancement de notre nouvel outil de sélection d'accessoires, maintenant disponible...
juillet 16, 2020
Les caméras à objectif double de comptage de personnes Hikvision peuvent faciliter la distanciation sociale. Nos...
juillet 08, 2020
Our new online brochure overviews the full line of Hikvision’s Highly Accurate Thermographic (HAT) skin-surface...

IMPORTANT! Ce modèle nécessite un logiciel non standard. N'installez pas de logiciel standard (par exemple, v.4.1.xx) sur ce modèle. Cela endommagerait définitivement votre système. Vous devez utiliser le logiciel personnalisé v.4.1.25 à partir de la page du produit iDS-9632NXI-I8/16S

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

En téléchargeant et en utilisant des logiciels et autres matériels disponibles sur ce site, vous acceptez d'être lié par les Conditions Générales d'Utilisation de HIKVISION. Si vous n'acceptez pas ces conditions, vous ne pouvez télécharger aucun de ces documents. Si vous êtes d'accord sur votre entreprise, vous déclarez et garantissez que vous avez le pouvoir de lier votre entreprise aux Conditions Générales d'Utilisation . Vous déclarez et garantissez également que vous avez l'âge légal de la majorité dans la juridiction dans laquelle vous résidez (au moins 18 ans dans de nombreux pays).