FAQ

What is the difference between the main stream and the sub stream?

Mainstream: is the primary video feed. Mainstream provides the highest video quality, and is the stream the DVR / NVR uses when saving footage to the internal hard disk drive (HDD). Mainstream settings can be adjusted to increase or decrease recording resolution. These settings will impact recording file size and available recording time. Hard Disk Drive (HDD)

Sub-stream: is the secondary video feed. Sub-stream provides a lower quality video stream, and is typically used to stream video to computers, smartphones, or tablets over the Internet. This allows you to reduce streaming quality for live or remote viewing, while maintaining higher quality on the mainstream for HDD recording and storage.

 

When is each one used?


Mainstream: is the primary video feed  mainly use for recording..
Sub-stream: is used mainly for remote viewing from computers, smartphones, or tablets over the Internet from outside the network..

 

How does bit rate relate to the Resolution and Frame rate?

The combination of frame rate and resolution based on the type of compression will need bandwidth necessary to accomplish. The higher the resolution/frame rate combination the more bandwidth or bit rate is necessary. The link below is to a bit rate chart that discusses in greater detail.

H.264+ Bit Rate Chart

 

Will the exported password reset XML file expire?

The password reset File exported via SADP, IVMS4200 and Batch configuration tool import/code procedure for password reset needs to be done within 3 days or it will expire.

Be sure not to power down or reboot the camera within this time frame.

What camera series' have reset button.

A list needs to be compiled.

How to manually factory reset a camera.

1. Press and hold down the reset button for 30 seconds while the camera is on then power it down.
2. Continue to hold the reset button down for a second 30 seconds then power it back up.
3. Continue to hold the reset button down for a final 30 seconds then let go of the button.

On IVMS-4200 the device is added manually and shows serial number and net detect is proper but camera(s) does not show on main view.

When the hikvision device is added incorrectly the first time by having one digit off on a port number or ip address and/or incorrect password or export to group was unchecked, The group of cameras does not get created. To avoid this from happening when adding, simply delete the incorrectly added device from device management and re-add again correctly or fix the issue by creating/adding the cameras to a group in the group tab.

Is it possible to have multiple IP cameras run to the NVR/Network via a single Ethernet cable?

Yes, See the FAQ on "Quick steps on how to add an IP camera to a plug and play NVR when on an external POE switch."

Can I purchase more camera licenses for my Hikvision NVR?

All Hikvision Hardware NVR’s have a fixed number of channels. Licenses cannot be purchased to increase the number of supported channels.

What steps can I take to increase recording time on a DVR/NVR without increasing storage space?

Setting the DVR/NVR to record only on motion and reducing quality’s frame rate, Resolution and Maximum bit rate will increase the recording time to the existing hard drive of the recorder.

Quick steps on how to add an IP camera to a plug and play NVR when on an external POE switch.

Before mounting the camera, connect it directly to the port number on the NVR built in POE switch corresponding to the channel it will be working on so it can plug and play. Once playing, using the NVR’s monitor output GUI go to:

-Menu >>> Camera Setup >>> Click edit button for the channel in question >>> Change Adding method button from “Plug and Play” to “Manual” >>> Enter the password of the NVR at bottom >>> click Ok.

--The camera will now work an external POE switch that will be connected directly to the NVR internal POE switch on the channel programmed.

How to add a third party IP camera to a Hikvision plug and Play NVR in a nutshell?

On the NVR monitor Output GUI:

-Menu >>> Camera Setup -Choose the channel number the camera is to be assigned to and make note of its IP address.

-Using the third party camera’s software discovery tool or browser interface, preconfigure the camera to noted IP address.

-Menu >>> Camera Setup >>> Click edit button for the channel in question >>> Change Adding method button from “Plug and Play” to “Manual” >>> Set the Protocol to the camera’s manufacturers name or OnVif >>> Enter the password of the camera at bottom >>> click Ok.

-The camera will now work an external POE switch that will be connected directly to the NVR internal POE switch on the channel programmed.

Why is the DVR/NVR beeping or has a there a triangle with an exclamation point on the lower right hand side of the recorder's monitor output?

The NVR is warning about an issue or event that it is programmed to notify about. If this symbol is clicked on, a list called Alarm/Exception list will appear explaining each notification or error the NVR is experiencing.

How to enable push notifications on Recorder/camera and enable receiving them on the hik-connect app based on VCA rules like line crossing or intrusion detection?

From the Recorder’s monitor output GUI, go to :

Menu >>> Camera Setup >>> VCA >>> Choose desired VCA type tab >>> Enable >>> Draw the line or region >>> Click “SET” button >>> Linkage Action (tab) >>> Place check on “Notify Surveillance Center” >>> Click “OK” >>> “Click Apply”

On Hik-Connect app:

Hik-Connect Page option (bottom) >>> Swipe the device to the left >>> Press the cog/gear setting button >>> Alarm Notification set to Enable.

Does Hikvision require any additional licensing fee?

No licensing fees required for non-Hik Central products.

How do I add multiple channels from a single encoder to a NVR?

Each video channel from an encoder will take up 1 NVR camera channel. All channels will be assigned the same IP as the single encoder, follow by different video ports for each of the different channels that are assigned.

What does it mean when I see a "no resource" error on the DVR/NVR's local live view?

"No resrouce" usually indicates that the NVR/DVR's graphical display has reached it's limits. You can resolve this by re-adjusting the video settings of the displaying camera channels. Reduce the resolution/fps/max bitrate settings for either main stream and or sub streams of the camera

Can I use Hik-Connect to setup a DDNS domain name?

Yes, you can create a domain name for hik-connect devices by logging in to www.hik-connect.com, go to device management and select the edit icon to create a customized domain name of the registered hik-connect device.

My Turbo Camera is not showin up on this existing DS-72XXHGHI-SH

Either Power issue or the Turbo camera has resolution beyond DVR capabilities. 3 MP-5MP

My FW update keeps failing

The FW file is either still zipped, wrong file, or file path too long in the browser

Does Hikvision require any additional licensing fee?

No licensing fees required.

How can I request an RMA for my Hikvision products

Click here for more detailed information on Hikvision USA RMA policy.

What kind of support will Hikvision provide in developing HEOP applications?

HEOP SDK and other referred tools are supported.For external help, independent software consultant is recommended. Please note that: any contract between the third party developers and this consultantcompany is established without Hikvision‘s involvement or responsibility.

Q:Is it possible to get stream and uncompressed (raw) audio data?

Yes. Hikvision provides interface to get audio ES data and uncompressed audiostream.

Q:Is H264/MJPEG ES stream supported?

 Yes. Hikvision provides two methods to get H264 ES stream, please refer toHEOP SDK documents for detailed information.

IMPORTANT! Ce modèle nécessite un logiciel non standard. N'installez pas de logiciel standard (par exemple, v.4.1.xx) sur ce modèle. Cela endommagerait définitivement votre système. Vous devez utiliser le logiciel personnalisé v.4.1.25 à partir de la page du produit iDS-9632NXI-I8/16S

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

En téléchargeant et en utilisant des logiciels et autres matériels disponibles sur ce site, vous acceptez d'être lié par les Conditions Générales d'Utilisation de HIKVISION. Si vous n'acceptez pas ces conditions, vous ne pouvez télécharger aucun de ces documents. Si vous êtes d'accord sur votre entreprise, vous déclarez et garantissez que vous avez le pouvoir de lier votre entreprise aux Conditions Générales d'Utilisation . Vous déclarez et garantissez également que vous avez l'âge légal de la majorité dans la juridiction dans laquelle vous résidez (au moins 18 ans dans de nombreux pays).