What camera series' have reset button.

A list needs to be compiled.

How to manually factory reset a camera.

1. Press and hold down the reset button for 30 seconds while the camera is on then power it down.
2. Continue to hold the reset button down for a second 30 seconds then power it back up.
3. Continue to hold the reset button down for a final 30 seconds then let go of the button.

Quick steps on how to add an IP camera to a plug and play NVR when on an external POE switch.

Before mounting the camera, connect it directly to the port number on the NVR built in POE switch corresponding to the channel it will be working on so it can plug and play. Once playing, using the NVR’s monitor output GUI go to:

-Menu >>> Camera Setup >>> Click edit button for the channel in question >>> Change Adding method button from “Plug and Play” to “Manual” >>> Enter the password of the NVR at bottom >>> click Ok.

--The camera will now work an external POE switch that will be connected directly to the NVR internal POE switch on the channel programmed.

How to enable push notifications on Recorder/camera and enable receiving them on the hik-connect app based on VCA rules like line crossing or intrusion detection?

From the Recorder’s monitor output GUI, go to :

Menu >>> Camera Setup >>> VCA >>> Choose desired VCA type tab >>> Enable >>> Draw the line or region >>> Click “SET” button >>> Linkage Action (tab) >>> Place check on “Notify Surveillance Center” >>> Click “OK” >>> “Click Apply”

On Hik-Connect app:

Hik-Connect Page option (bottom) >>> Swipe the device to the left >>> Press the cog/gear setting button >>> Alarm Notification set to Enable.

My Turbo Camera is not showin up on this existing DS-72XXHGHI-SH

Either Power issue or the Turbo camera has resolution beyond DVR capabilities. 3 MP-5MP

How to upgrade Hikvision IP camera firmware?

To upgrade the firmware of a Hikvision IP camera, first download the appropriate firmware from here. (Note: The firmware are region specific. Upgrading firmware developed for another region may cause damage to your product.)

  1. Once the proper firmware is downloaded, extract (unzip) the content of the .zip file onto the desktop of your computer.
  2. Log into the camera by using the Internet Explorer browser
  3. Go to the CONFIGURATION tab, then from BASIC CONFIGURATION, go to SYSTEM and select the MAINTENANCE tab.
  4. On the bottom of the page under the REMOTE UPGRADE section, click the BROWSE button to select the firmware file.
  5. Select the firmware named digicap.dav on your desktop and click the UPGRADE button.
  6. The camera will reboot after the firmware is successfully upgraded.

For further direction, please view the relevant technical bulletin below. Upgrading the Firmware on the Hikvision IP Camera

 

How do I download the latest firmware version for my Hikvision device?

Click here to find the latest firmware release for your Hikvision device.

Note: The firmware are region specific. Upgrading firmware developed for another region may cause damage to your product.

 

What is the default user name and password for Hikvision devices?

Hikvision has a strong commitment to our distributors and dealers, and their security needs are of the utmost importance to us. We have recently taken a number of steps to ensure that our surveillance products meet and exceed these security needs. Hikvision is introducing new firmware that will require users to create a password in order to activate their devices.

Note: All DVR/NVR/IP camera models are no longer shipped with a default password after a certain revision of firmware.

 

The Secure Activation feature is deployed in the following firmware revisions:

Device Type Model Number

Firmware Version

Value Series IP Camera

DS-2CD2xxx

v5.3.0

Smart Series IP Camera

DS-2CD4xxx v5.3.0

NVR/Hybrid

DS-9016HWI-ST

v3.1.5

DS-96xxNI-ST
DS-7716NI-SP/16

Plug-n-Play NVR

DS-76xxNI-EI(E2)/P v3.1.0

Turbo DVR

DS-72xxHGHI-SH

v3.1.6

DS-73xxHQHI-SH

 

For more information, please view the relevant technical bulletin:

 

How to assign a static IP address to my Hikvision device?

Download the SADP tool from here. The SADP tool will search any Hikvision products on the network and displays the information of the devices. This software can also be used to quickly configure the network information of the devices such as assigning a static IP address.

Note that the computer running the SADP software must be on the same network (physical subnet) as the Hikvision device.

 

How can I find the Hikvision IP devices on the network?

You can find all your IP devices by using the SADP (Search Active Device Protocol) software.

Download the SADP tool from here. The SADP tool will search any Hikvision products on the network and displays the information of the devices. This software can also be used to quickly configure the network information of the devices such as assigning a static IP address.

Note that the computer running the SADP software must be on the same network (physical subnet) as the Hikvision device.

 

What ports are needed to be forward for remote access?

By default, the following ports needs to be forwarded for remote access.

HTTP port 80 Used to connect via the web browser
Server port 8000 Used to connect via iVMS-4200 software and iVMS-4500 Mobile App
RTSP port 10554 Used for the video streaming
HTTPS port 443 Used to connect via the web browser using SSL encryption

 

 

 

 

Note: If the RTSP (Real Time Streaming Protocol) port is defaulted to 554 (on older model/firmware) it is recommended to change this port to 10554 or 1024 when experiencing connection issues over 3G/4G connection. 

 

How to fix Internet Explorer compatibility view issues?

When viewing the device using Internet Explorer (IE) 10 or 11 (32-bit), sometimes the content may not display properly. This may be caused by a browser incompatibility. To resolve the incompatibility issue, the IP address of the Hikvision device needs to be added to the compatibility view list.

For more detailed information on how to add the device to enable the compatibility view click here.

 

How to view my camera using Safari on MAC OS

In order to Live View using Safari on MAC OS, the Hikvision web plug-in for MAC OS needs to be downloaded and installed. Note: Please close all web browsers before installing the web plug-in.

Click here to download the MAC web plug-in for IP Cameras.

For detailed information, please view the relevant technical bulletin: How to install plug-in for MAC OS.

 

Where are the files saved to when downloading via the web browser?
  1. Log into the device using the web browser,
  2. Click on Configuration and then Local configuration / Local (dependent of the version of the web plug-in).
  3. On the right panel, you should see the default paths for the saved files.
Internet Explorer keeps prompting to download the web plugin

This is caused by Internet Explorer compatibility issues. If you are using IE 10 or 11, the page needs to be displayed using Compatibility view. To resolve this issue, the compatibility view mode needs to be turned on by adding the IP address of the Hikvision device to the compatibility view list.

For more detailed information on how to add the device to enable the compatibility view click here.

 

I have installed the SADP tool however I am still unable to detect my device.

You may need to update the WinPcap utility.

  1. Close the SADP software.
  2. Click here to download and install the latest WinPcap.
  3. Then run the SADP software again.

Also, make sure the computer is connected to the same subnet as the Hikvision devices.

If you are still having issue, click here to download the latest SADP software.

 

Which NAS servers are compatible with Hikvision IP cameras?

For more information on the supported NAS servers, please view the relevant technical bulletin:

 

The “Communication to Server Failed” error appears when registering to DDNS?

The Preferred DNS Server should not be blank and a public DNS server assigned. A public DNS server to input is Google’s free DNS Server 75.75.75.75 or 4.2.2.2. For detailed information, please view the relevant technical bulletin.

HiDDNS Troubleshooting

Remote Access of a DVR/NVR with HiDDNS

 

What are the default IP address of the IP cameras?

IP camera with firmware:

  • v5.2 or prior 192.0.0.64
  • v5.3 or later 192.168.1.64

 

How to change the date and time of an IP camera via web browser?
  1. Log into the IP camera using the web browser,
  2. Select CONFIGURATION,
  3. Select BASIC CONFIGURATION andthen select SYSTEM (on left side),
  4. Select TIME SETTINGS tab andinput the correct date and time,
  5. Click the SAVE button to applythe settings.

IMPORTANT! This model requires non-standard firmware. Do Not Install standard firmware (e.g. v.4.1.xx) on this model. Doing so will permanently damage your system. You must use custom firmware v.4.1.25 from the iDS-9632NXI-I8/16S product page.

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

By downloading and using software and other materials available via this website, you agree to be legally bound by HIKVISION General Terms of Use . If you don’t agree to these terms, you may not download or use any of those materials.

If you are agreeing on behalf of your company, you represent and warrant that you have legal authority to bind your company to the General Terms of Use above. Also you represent and warrant that you are of the legal age of majority in the jurisdiction in which you reside (at least 18 years of age in many countries).