Product Announcement

février 21, 2018
Hikvision a lancé sa nouvelle caméra DarkFighterX, une caméra dôme et réseau de surveillance, avec IR et zoom optique...
janvier 11, 2018
Hikvision, un chef de file en matière d’intelligence artificielle, d’apprentissage machine, de robotique et d’autres...
janvier 09, 2018
Un système de surveillance fourni par Hikvision Europe a permis de sécuriser le lycée Ducancoup, une école privée à...
janvier 05, 2018
Hikvision North America has launched the new and improved graphic user interface (GUI) 4.0, which offers enhancements...
janvier 02, 2018
Hikvision’s TurboHD surveillance technology uses a unique “tribrid” technology to deliver client savings using a...
décembre 27, 2017
A 4K PTZ security camera provided by Hikvision UK is helping the Salford City Council in Greater Manchester, England...
décembre 26, 2017
Hikvision specialty solutions offer versatile surveillance options for enterprise and specialized vertical markets...
décembre 26, 2017
Hikvision security cameras provided a surveillance solution to monitor training and soccer matches for Dutch football...
décembre 22, 2017
Thermal imaging sensors in Hikvision thermal surveillance cameras can detect infrared energy, which is emitted from...
décembre 18, 2017
Hikvision, based in the Chinese city of Hangzhou, recently announced that its DeepinView network PTZ security camera...
décembre 15, 2017
Hikvision’s TurboHD surveillance system simplifies the process of upgrading from analog to IP by allowing high-...
décembre 01, 2017
Hikvision corporate has launched a new addition to its Turbo HD 4.0 security camera lineup, providing more accurate...
novembre 30, 2017
Hikvision has enhanced its low light video surveillance technology with the release of DarkFighterX, applying the...
novembre 30, 2017
Hikvision Europe has released wireless bridges that work with its IP surveillance cameras to improve ease of...
novembre 28, 2017
Hikvision showcased its latest technology at the 21st Annual LLSSA (The Louisiana Life Safety & Security...
novembre 21, 2017
Hikvision North America, a leader in award-winning video surveillance products and solutions, has launched machine and...
novembre 20, 2017
La nouvelle technologie de surveillance DarkfighterX de Hikvision offre des images couleur intégrales dans des...
novembre 20, 2017
Hikvision qui est située dans la ville de Hangzhou, en Chine, a présenté ses solutions de vidéosurveillance à l’...
novembre 16, 2017
Hikvision a annoncé le lancement de sa nouvelle technologie DarkFighterX qui offre des images couleur nettes dans des...
novembre 16, 2017
  Hikvision a publié un rapport sur la technologie au sujet des avantages de l’apprentissage profond pour l’industrie...
novembre 13, 2017
Le siège social de Hikvision, situé dans la ville de Hangzhou, en Chine, a récemment annoncé le lancement de NVR 4.0,...
novembre 09, 2017
Le siège social de Hikvision, dans la ville de Hangzhou, en Chine, a récemment annoncé le lancement d’une nouvelle...
novembre 09, 2017
Le siège social de Hikvision, dans la ville de Hangzhou, en Chine, a récemment annoncé le lancement d’une nouvelle...
novembre 08, 2017
Le siège social de Hikvision qui est situé dans la ville de Hangzhou, en Chine, a présenté sa dernière technologie d’...

IMPORTANT! Ce modèle nécessite un logiciel non standard. N'installez pas de logiciel standard (par exemple, v.4.1.xx) sur ce modèle. Cela endommagerait définitivement votre système. Vous devez utiliser le logiciel personnalisé v.4.1.25 à partir de la page du produit iDS-9632NXI-I8/16S

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

En téléchargeant et en utilisant des logiciels et autres matériels disponibles sur ce site, vous acceptez d'être lié par les Conditions Générales d'Utilisation de HIKVISION. Si vous n'acceptez pas ces conditions, vous ne pouvez télécharger aucun de ces documents. Si vous êtes d'accord sur votre entreprise, vous déclarez et garantissez que vous avez le pouvoir de lier votre entreprise aux Conditions Générales d'Utilisation . Vous déclarez et garantissez également que vous avez l'âge légal de la majorité dans la juridiction dans laquelle vous résidez (au moins 18 ans dans de nombreux pays).