Company News

avril 05, 2018
  A surveillance system provided by Hikvision Canada Inc. was installed by Hikvision integrator OGSP (Off Grid...
avril 04, 2018
Two Hikvision articles made the “Top 10 Security Stories From March 2018” by Security Sales & Integration (SSI)....
mars 28, 2018
Video surveillance of Austin bomber Mark Anthony Conditt helped authorities identify him and track him down....
mars 27, 2018
A security system provided by Hikvision USA Inc., the North American leader in innovative, award-winning video...
mars 22, 2018
Hikvision USA Inc. is pleased to announce it was selected as the recipient of both “Supplier of the Year 2017” and...
mars 21, 2018
Leading publication Security Sales & Integration (SS&I) published a three-page article in its March (ISC West...
mars 19, 2018
At the PSA TEC conference this past week, March 12 – 16, 2018, PSA helped to build more than 200 care packages for...
mars 15, 2018
Hikvision USA Inc. worked with Hikvision integrator TAS Electronics in New York to furnish a full-scale surveillance...
mars 14, 2018
Hikvision will exhibit its latest innovations in surveillance and AI cloud at SECON in Seoul, South Korea, March 14...
mars 13, 2018
Hikvision USA Inc. released a promotional video for its upcoming US Cybersecurity Road Show 2018, which kicks off in...
mars 08, 2018
Today Hikvision USA Inc. announced the opening of its Source Code Transparency Center (SCTC), the first of its kind in...
mars 07, 2018
Surveillance cameras provided by Hikvision are helping to monitor South Africa’s Eskom, the national electricity...
mars 06, 2018
Hikvision announced solid year-over-year (YoY) revenue growth for 2017 with the release of its 2017 Fiscal Year...
mars 02, 2018
Hikvision will sponsor the 2018 Campus Safety Summit that will take place April 16-17, 2018 in Dallas, happening in...
mars 01, 2018
Today Hikvision announced that its US Cybersecurity Road Show will kick off Tuesday, March 27, 2018 in Los Angeles,...
février 28, 2018
Hikvision’s vertical business development team recently showcased its thermal PTZ security cameras at the Border...
février 27, 2018
Hikvision’s vertical business development team will showcase its latest surveillance solutions at the 13th annual ...
février 23, 2018
Le 15 février 2018, SP&T News a tenu sa troisième Mission 500 Hockey Classic annuelle, recueillant plus de 17 000...
février 21, 2018
Hikvision a lancé sa nouvelle caméra DarkFighterX, une caméra dôme et réseau de surveillance, avec IR et zoom optique...
janvier 11, 2018
Hikvision, un chef de file en matière d’intelligence artificielle, d’apprentissage machine, de robotique et d’autres...
janvier 10, 2018
Le service d’apprentissage et de développement Hikvision a récemment mis en ligne deux nouveaux cours en ligne...
janvier 09, 2018
Le cabinet de recherche mondial IHS Markit, selon son dernier rapport, a annoncé de Hikvision, premier fournisseur...
janvier 08, 2018
Une entrevue avec le président de Hikvision d’Amérique du Nord, Jeffrey He, au sujet de la cybersécurité, de la...
janvier 05, 2018
Hikvision North America has launched the new and improved graphic user interface (GUI) 4.0, which offers enhancements...

IMPORTANT! Ce modèle nécessite un logiciel non standard. N'installez pas de logiciel standard (par exemple, v.4.1.xx) sur ce modèle. Cela endommagerait définitivement votre système. Vous devez utiliser le logiciel personnalisé v.4.1.25 à partir de la page du produit iDS-9632NXI-I8/16S

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

En téléchargeant et en utilisant des logiciels et autres matériels disponibles sur ce site, vous acceptez d'être lié par les Conditions Générales d'Utilisation de HIKVISION. Si vous n'acceptez pas ces conditions, vous ne pouvez télécharger aucun de ces documents. Si vous êtes d'accord sur votre entreprise, vous déclarez et garantissez que vous avez le pouvoir de lier votre entreprise aux Conditions Générales d'Utilisation . Vous déclarez et garantissez également que vous avez l'âge légal de la majorité dans la juridiction dans laquelle vous résidez (au moins 18 ans dans de nombreux pays).