Events

mars 16, 2018
ISC West has announced its 2018 keynote series featuring three high-profile speakers, including Jeff Crume of IBM,...
mars 14, 2018
Hikvision will exhibit its latest innovations in surveillance and AI cloud at SECON in Seoul, South Korea, March 14...
mars 13, 2018
Hikvision USA Inc. released a promotional video for its upcoming US Cybersecurity Road Show 2018, which kicks off in...
mars 09, 2018
SecurityInfoWatch.com reported that registration has opened for ASIS International’s 28th annual New York City...
mars 05, 2018
Registration has opened for the inaugural Cyber: Secured Forum 2018, hosted by PSA Security Network, ISC Security...
mars 05, 2018
TEC, the security conference hosted by security cooperative PSA Security Network, is hosting a State of the Industry...
mars 02, 2018
Hikvision will sponsor the 2018 Campus Safety Summit that will take place April 16-17, 2018 in Dallas, happening in...
mars 01, 2018
Today Hikvision announced that its US Cybersecurity Road Show will kick off Tuesday, March 27, 2018 in Los Angeles,...
février 28, 2018
Hikvision’s vertical business development team recently showcased its thermal PTZ security cameras at the Border...
février 27, 2018
Hikvision’s vertical business development team will showcase its latest surveillance solutions at the 13th annual ...
février 26, 2018
Security Systems News (SSN) is seeking survey respondents for its new ISC West 2018 news poll, gathering information...
février 26, 2018
Security Sales & Integration (SSI) announced the unveiling of details for ASIS International’s newly rebranded...
février 22, 2018
Gordon Smith, directeur régional du développement commercial d’Hikvision au Canada, animera une séance interactive sur...
février 21, 2018
Security Sales and Integration (SSI) a rapporté que l’Electronic Security Expo (ESX) a annoncé son conférencier d’...
février 19, 2018
La Security Industry Association (SIA) a annoncé qu’elle organisera un séminaire de formation sur la gestion de projet...
janvier 12, 2018
Le réseau de sécurité PSA, les événements sur la sécurité d’ISC et la Security Industry Association (SIA) lanceront un...
janvier 10, 2018
ISC West en 2018, le plus grand événement annuel de l’industrie de la sécurité, a annoncé sa gamme d’éducation...
décembre 20, 2017
In conjunction with technology partner Camcloud, members of Hikvision USA Inc.’s Southeast team demonstrated the...
décembre 19, 2017
ASIS International recently announced the rebranding of its ASIS Annual Seminar and Exhibits to its new name, the...
décembre 19, 2017
In its recently released "Security 50 Ranking and Reports" a&s magazine announced that Hikvision took the No. 1...
décembre 18, 2017
Hikvision showcased its latest video surveillance solutions at the AEC (annual education conference) and trade show...
décembre 14, 2017
Hikvision’s director of cybersecurity, Chuck Davis, will host the education session “The Age of Cybersecurity:...
décembre 06, 2017
Young professionals at SIA member companies have until Friday, Dec. 8 to apply for a portion of $30,000 in scholarship...
décembre 05, 2017
More than 150 integrators, end users, A&Es and other interested parties came to the Living Arts Centre Mississauga...

IMPORTANT! Ce modèle nécessite un logiciel non standard. N'installez pas de logiciel standard (par exemple, v.4.1.xx) sur ce modèle. Cela endommagerait définitivement votre système. Vous devez utiliser le logiciel personnalisé v.4.1.25 à partir de la page du produit iDS-9632NXI-I8/16S

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

En téléchargeant et en utilisant des logiciels et autres matériels disponibles sur ce site, vous acceptez d'être lié par les Conditions Générales d'Utilisation de HIKVISION. Si vous n'acceptez pas ces conditions, vous ne pouvez télécharger aucun de ces documents. Si vous êtes d'accord sur votre entreprise, vous déclarez et garantissez que vous avez le pouvoir de lier votre entreprise aux Conditions Générales d'Utilisation . Vous déclarez et garantissez également que vous avez l'âge légal de la majorité dans la juridiction dans laquelle vous résidez (au moins 18 ans dans de nombreux pays).