HikWire Blog

July 07, 2022
If you missed our June 21 webinar on the new Android All-In-One Video Intercom Indoor Station and Hikvision Intercom...
July 06, 2022
Hikvision is excited to introduce the new AcuSense K-Series plug and play NVR and the Turbo AcuSense DVR with POC (...
July 05, 2022
Hikvision’s groundbreaking ColorVu technology enhances security and safety and is available in a wide range of cameras...
July 01, 2022
Ransomware, a diabolical form of malware that is silently installed on someone’s computer after they fall for a...
June 30, 2022
Recently updated and easier to use, Hikvision’s Learning & Development website helps you and your team get up to...
June 29, 2022
Hikvision’s Value IP Cameras and AcuSense NVRs pack outstanding value into a vast range of form factors, offering...
June 28, 2022
Desktop and web clients can access HikCentral Professional with upgraded features from anywhere with HikCentral...
June 24, 2022
Security Magazine recently released an article revealing that phishing attacks hit an all-time high in the first...
June 23, 2022
If you’ve been considering upgrading your security system, now is a great time. As part of Hikvision’s Project...
June 22, 2022
Hikvision has a great product line of cameras equipped with ColorVu technology. ColorVu technology offers a great...
June 21, 2022
The AcuSense M-Series DVR (ids-72xxHxHI-Mx/S) now comes equipped with Motion Detection 2.0 for all analog channels....
June 17, 2022
Hikvision is dedicated to keeping you safe from cyberattacks. In today’s blog, we will be discussing smishing—an SMS-...
June 16, 2022
Our goal here at Hikvision is to make sure you stay up to date with the latest security technology to ensure the best...
June 15, 2022
Hikvision has several exciting new products featuring low-light technology for better imaging at night and in strong...
June 14, 2022
Hikvision has a wide selection of multi-functional intercom products to enhance access control and security. These...
June 13, 2022
Dealers Can Now Test High End Hikvision Product Innovations at the Reduced Price of 50% Off Now through August 31,...
June 10, 2022
The DF3T TurboHD Camera with ColorVu from Hikvision offers amazing features and technology that make it the optimal...
June 09, 2022
Hikvision’s AcuSense M-Series DVR provides recording management that is now easier than ever. With seamless, remote...
June 08, 2022
Hikvision’s HeatPro Bi-Spectrum Thermal Camera Series provides proactive protection of staff, assets, and property....
June 07, 2022
Hikvision is excited to invite you to join our webinar for the new Android All-In-One Video Intercom Indoor Station on...
June 03, 2022
SDM magazine recently published an article on video security and cybersecurity risk, where Hikvision’s VP of Global...
June 02, 2022
Hikvision USA has a YouTube channel that illustrates and highlights many product features and functionalities. This...
June 01, 2022
Hikvision’s new Premium ColorVu Camera Kit offers a convenient grab-and-go experience with exceptional night vision...
May 31, 2022
Hikvision recently released two new panoramic cameras with ColorVu technology. Designed for wide area video coverage...

IMPORTANT! This model requires non-standard firmware. Do Not Install standard firmware (e.g. v.4.1.xx) on this model. Doing so will permanently damage your system. You must use custom firmware v.4.1.25 from the iDS-9632NXI-I8/16S product page.

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

By downloading and using software and other materials available via this website, you agree to be legally bound by HIKVISION General Terms of Use . If you don’t agree to these terms, you may not download or use any of those materials.

If you are agreeing on behalf of your company, you represent and warrant that you have legal authority to bind your company to the General Terms of Use above. Also you represent and warrant that you are of the legal age of majority in the jurisdiction in which you reside (at least 18 years of age in many countries).