Product Announcement

May 10, 2022
Hikvision’s exceptional 2nd Gen AcuSense PCI Series cameras offer many exciting benefits and customizable features....
May 04, 2022
Hikvision’s Panoramic Cameras with ColorVu technology deliver extremely colorful images through wide, 180-degree...
April 27, 2022
Hikvision’s Modular IP Video Intercom Kit (DS-KIS602) is an intercom solution that enables you to greet visitors and...
April 26, 2022
The next generation iDS-7 Series DeepinView cameras are fully loaded and boosted by AI video analytics technology....
April 19, 2022
Hikvision is excited to announce the upgraded 256 x 192 resolution HeatPro Bi-Spectrum Thermal Cameras. The latest...
April 14, 2022
Hikvision continues to enhance its next-generation technology — demonstrated once again in the new TandemVu PTZ camera...
April 11, 2022
With HikCentral Professional VMS 2.2, you can receive alerts on your smartphone, web application, or PC from any...
April 06, 2022
Hikvision’s upgraded second generation Value IP Cameras and AcuSense NVRs come equipped with several enhanced key...
April 05, 2022
If you missed the March 15 MinMoe Terminal Webinar, there is still time to catch a replay on the Hikvision Learning...
March 29, 2022
Hikvision is excited to introduce the new TandemVu ColorVu PTZ cameras. These new cameras provide an innovative...
March 25, 2022
Hikvision’s HeatPro Bi-Spectrum Cameras create a fantastic solution to professional property protection through elite...
March 24, 2022
Hikvision’s Value IP Cameras and AcuSense Network Video Recorders (NVRs) now pack upgraded functionality with better...
March 23, 2022
Keeping remote areas safe and free from theft is difficult, especially when power supplies and Ethernet cables don’t...
March 17, 2022
Security professionals will be excited about three new Hikvision releases that meet the most important challenges of...
March 16, 2022
Hikvision’s newest compact Value Series MinMoe Multi-Modal Biometrics Reader delivers outstanding access control and...
March 10, 2022
Here at Hikvision, we aim to bring you the latest technology to ensure you and your assets are continuously protected...
March 09, 2022
Expand your knowledge of the Hikvision MinMoe Multi-Functional Terminals Series (DS-K1T342DWX) by attending our...
March 03, 2022
Hikvision continues to deliver technology with improvements that work for you and your business. Our newest 3rd Gen...
March 04, 2022
Hikvision proudly announces the release of the HikCentral professional 2.2 central video management system (VMS). This...
March 02, 2022
Hikvision’s new Advanced Series 8 MP 4G Solar-Powered Security System has arrived. Compared to the original, standard...
February 25, 2022
Our DS-2CD25X3 Mini Dome and DS-2CD2E43 In-Ceiling Dome have now been upgraded with enhanced image and video quality...
February 23, 2022
The 2nd Gen Value IP Cameras and AcuSense NVRs have been upgraded with the latest functionality, continuing to prove...
February 22, 2022
Recycling companies face a major risk of fire, and this threat becomes greater during their off-hours when no one is...
February 18, 2022
Hikvision’s MinMoe Touchless Identity Authentication Terminal changes the biometric access control game with new, high...

IMPORTANT! This model requires non-standard firmware. Do Not Install standard firmware (e.g. v.4.1.xx) on this model. Doing so will permanently damage your system. You must use custom firmware v.4.1.25 from the iDS-9632NXI-I8/16S product page.

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

By downloading and using software and other materials available via this website, you agree to be legally bound by HIKVISION General Terms of Use . If you don’t agree to these terms, you may not download or use any of those materials.

If you are agreeing on behalf of your company, you represent and warrant that you have legal authority to bind your company to the General Terms of Use above. Also you represent and warrant that you are of the legal age of majority in the jurisdiction in which you reside (at least 18 years of age in many countries).