HikWire Blog

April 27, 2023
Hikvision’s collection of innovative, multi-sensor cameras delivers multi-directional monitoring for advanced security...
April 26, 2023
Hikvision brings you the latest in innovative technology with our new Smart Hybrid Light ColorVu Cameras! Working in a...
April 25, 2023
Have you checked out our broad lineup of cameras with ColorVu lately? From panoramic to HD and IP kits, we have an...
April 21, 2023
Vulnerabilities are bugs, flaws, or weaknesses in applications, operating systems, and software components that can be...
April 20, 2023
We’ve released two 7-series DeepinView, AI-powered License Plate Recognition (LPR) cameras in a dome and bullet model...
April 19, 2023
Introducing the latest in our intercom models, a Y-Series video intercom that works perfectly as a replacement for the...
April 18, 2023
Hikvision’s TurboHD lineup enables upgrading analog security cameras to HD-quality IP cameras without the costs or...
April 14, 2023
Security Magazine recently released an article covering ways small and medium-sized businesses (SMBs) can shore up...
April 13, 2023
Hikvision’s ColorVu + X technology is revolutionizing low-light imaging with its exceptional color rendering...
April 12, 2023
Hikvision’s 5 MP AcuSense Fisheye Network camera (DS-2CD3956G2-ISU) features our unique AcuSense technology. It’s...
April 11, 2023
With our new ColorVu IP kits, you can upgrade to better security easily, with bundles featuring 4, 6 or 12 cameras and...
April 07, 2023
Hikvision is committed to cybersecurity and offers insights into meaningful and valuable trends and practices in...
April 06, 2023
The new ColorVu eSSD 2 MP/4-CH Bundle Kit includes four turret TurboHD cameras, a reliable DVR with motion detection 2...
April 05, 2023
Here at Hikvision, we’re constantly searching for ways to elevate your security in cost-effective ways. We’re excited...
April 04, 2023
Hikvision is committed to delivering consistent innovation to the security industry. The company recently announced in...
March 31, 2023
Ransomware attacks are still a major problem within online cybersecurity today. Hikvision wants to keep our customers...
March 30, 2023
Hikvision's innovative PoE Network Switches are available in Hi-PoE, Gigabit Smart, and 100 Mbps Smart managed...
March 29, 2023
Hikvision is proud to introduce another way to simplify vehicle management with the new Dome LPR cameras (iDS-...
March 28, 2023
We’re excited to announce the release of two new models in our M-Series NVRs. Here at Hikvision, we always aim to...
March 23, 2023
Institutions around the globe are rolling out education video solutions to improve learning outcomes, boost campus...
March 24, 2023
According to a recent article in Security Magazine, 31% of organizations saw users fall for phishing attacks last year...
March 22, 2023
Have you ever looked for a security camera with easy installation, high quality video, and cost-effectiveness?...
March 21, 2023
If you haven’t yet, be sure to take advantage of our current promotion on video intercom, access control, and network...
March 17, 2023
Hikvision fully understands the importance of cybersecurity best practices within any kind of connected organization....

IMPORTANT! This model requires non-standard firmware. Do Not Install standard firmware (e.g. v.4.1.xx) on this model. Doing so will permanently damage your system. You must use custom firmware v.4.1.25 from the iDS-9632NXI-I8/16S product page.

View the most updated version of this document here:

https://techsupportca.freshdesk.com/en/support/solutions/articles/17000113531-i-series-nvr-firmware-upgrade-instructions

 

The I-series NVR (such as the DS-7716NI-I4) is one of Hikvision's most popular and feature-rich recorders. As such, many firmware revisions have been introduced over the years to continually ensure the product is compatible with the newest technology available. Due to the many revisions, we recommend that the user closely follows the instructions below in order to reduce the amount of time spent as well as the chance of failure.

 

Database Optimization and Repair

As more affordable IP cameras are introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.

 

After upgrading to v4.X, the recorder database will need to be converted and optimized. If you are experiencing issues where playback is expected but not found, make sure "Database Repair" is performed as indicated in the procedures and scenarios below.

 

Preparing the Upgrade

Before proceeding with upgrade, it is recommended that NVR configuration file is exported from the NVR over the network or on to a local USB drive.

 

Upgrading from v3.4.92 build 170518 or Older

  1. All recorders must reach v3.4.92 before proceeding further. Upgrading from versions before v3.4.92 directly to any version of v4.X will likely cause the recorder to fail.
  2. If the recorder is already at v3.4.92, a full factory default is highly recommended before upgrading to any version of v4.X. There is a high chance of unit failure (requiring RMA) if the unit is not defaulted before upgrade.
  3. After reaching v3.4.92 and performing a full factory default, an upgrade directly to v4.50.00 is acceptable.
  4. After the upgrade is completed and the recorder is reprogrammed, it may be beneficial to perform a Database Repair. For details, refer to the section "Database Optimization and Repair" above.
  5. To verify repair progress, you may refer to the HDD status, or search the recorder log for repair started and stopped entries. Note that while the HDD is repairing, new recordings are still being made, but some existing recordings may not be searchable until repair is complete.
  6. If you continue to observe playback issues after database repair, ensure there are no power, network, or motion detection issues. Should the problem persist, contact technical support.

 

Upgrading from Any v4.X Build to v4.50.00.

  1. Any v4.X build can be upgraded directly to v4.50.00.
  2. Export configuration is highly recommended before performing the upgrade.
  3. If upgrading from any v4.X version that was not v4.22.005, a Database Repair is recommended. Refer to Step 4 and onwards in the previous section.

 

Downgrading

Downgrading is not recommended. Due to new features and parameters constantly being added, downgrading may cause the NVR to factory default itself or require a manual default to operate properly.

View the most updated version of this document here:
K-Series DVR upgrade instruction
The Turbo 4 Hybrid DVR K series has multiple models and across different platform and chipset. It also has similar firmware development of other recording product line; DVR K series has also introduced the GUI4.0 to ensure the series to be compatible to the newest technology available. The new database architecture is also brought into the DVR firmware v4.0 to be future proof and for better recording search experience. 
 


Database Optimization and Repair

As more affordable cameras introduced over time with greater video resolution and data sizes, more efficient database management also becomes necessary. The introduction of firmware v4.0 brought about a new database architecture in order to be futureproof.
After upgrading to v4.X, the recorder database will need to be converted and optimize. If you are experiencing issues, where playback is expected but not found, please make sure to perform "Database Rebuild" as indicated in the procedures and scenarios below.
 


Preparing the Upgrade

Before proceeding with upgrade, it is recommend exporting DVR configuration file from the DVR over the network or on to a local USB drive.

 

Action after firmware upgraded 

1. Upgrade the DVR according to the chart above. 

2. Reconfirming Channel's Recording Schedule 

    - Confirm channel's recording schedule is enable. 

    - Check if the channel is on correct recording schedule.

3. Double Check Storage Setting

    - Make sure all channel are assigned to record on its HDD group when the Storage setting is under Group Mode. 

4. Perform Database Rebuild locally. 

    • Some version above support Database Rebuild via web access - K51 and K72

    • Perform Database Rebuild regardless if system is having any database issue symptom. 

    • Database Rebuild process is average ~30 to 60min per TB. The process may still varies depends recording data.

    • After Database Rebuild - Check log to confirm Database Rebuild has went thru properly. 

    • If Database Rebuild Started and Stopped log has been log only within few minutes. Database rebuild may not has been completed properly. It is strongly recommend performing the Database Rebuild again.

    • To check log > System > Log > Information > Database Rebuild Started and Stopped.

    • If the log option is not available - access system via SSH can also obtain similar result.

5. Recording Data is still missing after database rebuild process. 

If the data has not been recorded or has been overwritten, Database rebuild process is not able retrieve those lost data. Have the system upgraded to the latest available firmware version above to prevent any future data lost is strongly recommended for all application.

 

 

 

 

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the DS-76xxNI-Q1(2)/P NVRs, also known as “Q series.”

 

These changes do not have any effect on the performance, specifications, or the user interface of the NVRs. For the ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

 

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

 

  • The C-Version NVRs must use firmware version v4.31.102 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v4.30.085 or older.

 

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

In light of the global semiconductor shortage, Hikvision has made some hardware changes to the Value Express Series NVRs

These changes do not have any effect on the performance and specification of the recorders. For ease of reference, these modified units are known as “C-Version” units. This is clearly indicated on the NVR label and on the box by the serial number.

The only difference between the “C-Version” and “non-C-Version” is the firmware. The firmware is not interchangeable:

  • The C-Version NVRs must use firmware version v4.30.216 or higher.
  • The non-C-Version (Q series) NVRs must use firmware version v3.4.104 or older.

Please do not be alarmed if a “Firmware Mismatch” message pops up on the screen during the firmware upgrade. This simply means that the firmware does not match the NVR’s hardware. Simply download the correct firmware and the upgrade will go through without any issue.

By downloading and using software and other materials available via this website, you agree to be legally bound by HIKVISION General Terms of Use . If you don’t agree to these terms, you may not download or use any of those materials.

If you are agreeing on behalf of your company, you represent and warrant that you have legal authority to bind your company to the General Terms of Use above. Also you represent and warrant that you are of the legal age of majority in the jurisdiction in which you reside (at least 18 years of age in many countries).